Back to top
07971405467
Send Inquiry


                          Rochem Passivating Liquid

                          Rochem Passivating Liquid
                          Rochem Passivating Liquid
                          Rochem Passivating Liquid

                          Rochem Passivating Liquid Specification

                          • Color
                          • Clear
                          • Use
                          • For Membrane Cleaning Purpose
                          • Type
                          • Rochem Passivating
                          • Pack Type
                          • Drum and Bucket
                           

                          Rochem Passivating Liquid Trade Information

                          • Minimum Order Quantity
                          • 210 Gallons
                          • Payment Terms
                          • Cash Advance (CA)
                          • Supply Ability
                          • 1000 Gallons Per Day
                          • Delivery Time
                          • 5 Days
                          • Sample Available
                          • No
                          • Packaging Details
                          • 25 Kg
                          • Main Export Market(s)
                          • Asia
                          • Main Domestic Market
                          • All India
                          • Certifications
                          • Liquid for passivating austenitic stainless steel Rochem Passivating Liquid is based on nitric acid and non-ionic surface active substances. The product provides austenitic stainless steel with a protective oxide layer after it has been pickled. The metal is then passive. Rochem Passivating Liquid, undiluted, is suitable for use only on austenitic stainless steel. Application Rochem Passivating Liquid is used mainly for the passivation of pickled installations and tanks. It can be applied in the following ways: 1. by circulation 2. by spraying Direction for use General A passivating treatment with Rochem Passivating Liquid can only take place if the steel has been pickled previously (i.e. treated with Rochem Pickling Liquid). Circulation method This method is applied mainly in pipe systems. Fill the system with undiluted cold Rochem Passivating Liquid. The time taken for treatment is approx. 2 hours. Drain the system and rinse thoroughly with demineralized water. N.B. Before disposing the passivating fluid it should be neutralised. For this use slaked lime. Spraying This method is generally used in tanks with a tank washing device which is resistant to our product Rochem Passivating Liquid. The Passivating Liquid fluid is sprayed undiluted using a spraytime of approx. 15 minutes. After this rinse thoroughly with plenty of water using, preferably, demineralised. Properties Strong acidic product. Contains nitric acid. Fully miscible with water. Undiluted it is suitable for use only on austenitic stainless steel. When diluted it is suitable for cleaning aluminium. Specific gravity (at 20 C) : approx. 1.1 kg/ltr. Flashpoint c.c. : none pH (1% solution) : approx. 1.0
                           

                          About Rochem Passivating Liquid

                          Liquid for passivating austenitic stainless steel Rochem Passivating Liquid is based on nitric acid and non-ionic surface active substances. The product provides austenitic stainless steel with a protective oxide layer after it has been pickled. The metal is then passive. Rochem Passivating Liquid, undiluted, is suitable for use only on austenitic stainless steel.
                          Application Rochem Passivating Liquid is used mainly for the passivation of pickled installations and tanks. It can be applied in the following ways: 1. by circulation 2. by spraying
                          Direction for use General A passivating treatment with Rochem Passivating Liquid can only take place if the steel has been pickled previously (i.e. treated with Rochem Pickling Liquid). Circulation method This method is applied mainly in pipe systems. Fill the system with undiluted cold Rochem Passivating Liquid. The time taken for treatment is approx. 2 hours. Drain the system and rinse thoroughly with demineralized water. N.B. Before disposing the passivating fluid it should be neutralised. For this use slaked lime. Spraying This method is generally used in tanks with a tank washing device which is resistant to our product Rochem Passivating Liquid. The Passivating Liquid fluid is sprayed undiluted using a spraytime of approx. 15 minutes. After this rinse thoroughly with plenty of water using, preferably, demineralised.
                          Properties Strong acidic product. Contains nitric acid. Fully miscible with water. Undiluted it is suitable for use only on austenitic stainless steel. When diluted it is suitable for cleaning aluminium. Specific gravity (at 20C) : approx. 1.1 kg/ltr. Flashpoint c.c. : none pH (1% solution) : approx. 1.0

                          Price 140.0 INR/ Liter

                          • Minimum Order Quantity
                          • 210 Gallons
                          • Supply Ability
                          • 1000 Gallons Per Day
                          • Delivery Time
                          • 5 Days
                          • Main Domestic Market
                          • All India
                          • Main Export Market(s)
                          • Asia
                          Tell us about your requirement
                          product

                          Price:

                          Quantity
                          Select Unit

                          • 50
                          • 100
                          • 200
                          • 250
                          • 500
                          • 1000+
                          Additional detail
                          Mobile number

                          Email

                          More Products in Others Category

                          Rochem Pickling Liquid

                          Rochem Pickling Liquid

                          Minimum Order Quantity : 210 Gallons

                          Use : For Cooling Towers or any Other Open Cooling Water System

                          Type : Rochem Pickling

                          Pack Type : Drum and Bucket

                          Color : Clear or Brown

                          AGIP Hydraulic Oils

                          AGIP Hydraulic Oils

                          Price Range 100.00 - 1000.00 INR / Liter

                          Minimum Order Quantity : 210 Liters

                          Use : For Cranes and Machinery Purpose

                          Type : Hydraulic Oils

                          Pack Type : Drum and Bucket

                          Molykote P 37 Thread Paste

                          Molykote P 37 Thread Paste

                          Price Range 100.00 - 1000.00 INR / Liter

                          Minimum Order Quantity : 210 Liters

                          Use : For Threaded Connections

                          Type : Ultrapure High Temperature Paste

                          Pack Type : Can

                          Color : White,Black and Brown

                          Anti Micropitting Gear Oil

                          Anti Micropitting Gear Oil

                          Price Range 100.00 - 1000.00 INR / Liter

                          Minimum Order Quantity : 210 Liters

                          Use : For Industrial Gear Purpose

                          Type : Gear Oil

                          Pack Type : Drum